Practical Experience Feedback on VFD Based Level Control

This is very practical and useful solution for all dairy plants using HTST pasteurizer

We have implemented same system in our plant and observed power saving of thirty to forty percent and zero seal failure

Traditional float valve system causes milk churning and back pressure on pump but VFD with level transmitter gives smooth control and energy saving

Investment is around fifty thousand only and ROI is within six months

Highly recommended for 5 KLPH to 20 KLPH pasteurizers

Keep float valve as backup safety for emergency